Usage
phm2pj projection-filename number-detectors number-views [options...]
Options
- -phantom |
Select a standard phantom.
|
- -phmfile | Reads a user-created phantom file. |
- -geometry |
Sets the scanner geometry. Valid values are:
|
- -nray | Number of samples per each detector |
- -rotangle | The rotation angle as a fraction of a circle. For parallel geometries use a rotation angle of 0.5 and for equilinear and equiangular geometries use a rotation angle of 1. The default is to use to appropriate rotation angle based on the geometry. |
- -view-ratio | Sets the field of view as a ratio of the diameter of the phantom. For normal scanning, the default value of 1.0 is optimal. |
- -scan-ratio | Sets the length of scanning as a ratio of the view diameter. For normal scanning, the default value of 1.0 is optimal. |
- -focal-length | Sets the distance between the radiation source and the center of the object as a ratio of the radius of the object. For parallel geometries, a value of 1.0 is optimal. For other geometries, this should be at least 2.0 to avoid artifacts. The default value is 2. |